Uploaded image for project: 'PROFINET IO-Controller V3'
  1. PROFINET IO-Controller V3
  2. PSPNMV3-473

Reject Alarm Acknowledge Request before Alarm Response

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.2.1.0
    • Fix Version/s: V3.2.2.0, V3.3.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      If an alarm is received the following sequence shall be strictly followed (by application and protocol stack). Violation (e.g. wrong alarm acknowledge request) shall detected and reported.

      1. Protocol stack generates Alarm Indication for application
      2. Application generates Alarm Response for protocol stack
      3. Application send Alarm Acknowledge Request to protocol stack
      4. Protocol stack acknowledges alarm on network and generates Alarm Acknowledge Confirmation to application

       

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: