Uploaded image for project: 'PROFINET IO-Controller V3'
  1. PROFINET IO-Controller V3
  2. PSPNMV3-406

RCX_GET_DPM_IO_INFO_REQ reports wrong IO data length

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.1.0.0
    • Fix Version/s: V3.2.0.2, V3.3.0.0
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW 15-16
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      The generic service RCX_GET_DPM_IO_INFO_REQ shall only return the length of the real IO data. Currently the length reported contains the slave status bitlists which is incorrect.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: