First two data bytes of PNIO_APCTL_CMD_WRITE_REQ set to zero

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.1.2.0, V3.2.0.0
    • Fix Version/s: V3.2.0.1, V3.3.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      When application uses the PNIO_APCTL_CMD_WRITE_REQ service to write a record object, the first two bytes of write data are overwritten with zero value. It is expected that the data is written as specified by application.