Uploaded image for project: 'PROFINET IO-Controller V3'
  1. PROFINET IO-Controller V3
  2. PSPNMV3-381

DCP Hello test fails during normal netload class III (certification issue)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.1.0.0
    • Fix Version/s: V3.2.0.0, V3.3.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      During normal netload class III Testcase 53 DCP-Hello-Frames fails .
      The controller cant' stand dcp hello frames, no cyclic frames are send and AppReady request will not be confirmed but instead read record requests are dispatched apparently furthermore.

        Attachments

        1. C010C000.nxf
          387 kB
        2. Modifications PNM Certification.zip
          7 kB
        3. NLT-DCP-Hello_Testcase__ERRORS(Teil1+2).zip
          4,27 MB
        4. noAppReadyCnf.PNG
          noAppReadyCnf.PNG
          193 kB
        5. process_hello.png
          process_hello.png
          208 kB
        6. WDT_Error.PNG
          WDT_Error.PNG
          201 kB

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    RAamidi Redouane Aamidi
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: