Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.1.0.0
    • Fix Version/s: V3.1.0.2, V3.1.2.0, V3.2.0.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      When a submodule is plugged into a device the profinet controller does not sent parameter records for the corresponding submodule to the device. It is expected that all parameter records corresponding to the plugges submodule are sent to the device.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  AMesser Andreas Messer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: