      Description

      An API needs to be added to configure IsochroneousModeData.
      The existing service "PNM_AP_CFG_RECORD_REQ_T" shall be extended by defining a new PNM_AP_CFG_PRM_TYPE_E for IsoM parameters.

      A check shall be implemented that ALL submodules with IsoM parameters use the same value for T_IO_Input and T_IO_Output.