DPM is uninitilized which leads to uninitilized data on the bus

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: V3.0.30_MS_IRT
    • Fix Version/s: V3.0.40.0
    • Labels:
      None
    • Sprint:
      PI Sprint KW 30/31 2015
    • Account:
      SPC Profinet Master (SPCPROFINETMA)
    • Story Points:
      1

      Description

      If after firmware download and firmware configuration the user does not write IO data to DPM the firmware sends random (not initialized) data to the network. It may happen that the IOPS of a submodule has its valid bit set which lets the IO Device use the invalid data.