Uploaded image for project: 'PROFINET IO-Controller'
  1. PROFINET IO-Controller
  2. PSPNM-476

BUS ON flag can be triggered in unconfigured stack state when using netX Transport driver or mailbox RCX_START_STOP_COMM_REQ

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.9.1
    • Fix Version/s: V2.7.1.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      While stack is not configured (RUN flag is clear), BUS ON flag can be triggered via the netX Transport Driver. Such action is not possible via CIFX Driver.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  DDimitrov Dimitar Dimitrov
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: