get switch statistics does not work correctly when link state changes

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V2.6.5.0
    • Fix Version/s: V2.6.6.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      the new service Get_Switch_Statistics does not work correctly.
      when a link of port 1 changes from UP to DOWN and the data is read the stack still states "link up".

      in addition the handling of portNumber is incorrectly implemented. port 0 according to IO-Controller API is mapped to port 0 of DrvEdd which is incorrect (shall be port 1 of DrvEdd).
      This leads to strange ulValidFlags for Port0