Uploaded image for project: 'PROFINET IO-Controller'
  1. PROFINET IO-Controller
  2. PSPNM-418

Wrong hardware options on CIFX 104C-RE\F

    Details

    • Type: Bug
    • Status: Confirmed
    • Priority: Minor
    • Resolution: Unresolved
    • Affects Version/s: V2.6.5.0
    • Fix Version/s: None
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      On CIFX 104C-RE\F (Rev. 5 with AIFX-RE) hardware options 0 and 1 are set to 0xFFFB (I2C Interface), when firmware is active. According to DPM manual these values should be replaced after detecting the connected AIFX.
      When 2nd StageBootloader is active, hardware options 0 and 1 are 0x0080 (Ethernet) as expected.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  et et
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: