Overlapping Input DPM offsets of submodules with IRT Cycle counter not detected

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.1.0.2, V1.2.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If the stack is configured to copy the value of the current local cycle counter to the consumer data of IO device (DPM input area), when plugging a submodule using Plug service overlapping of IO data offset with IRT cycle counter offset is not detected.   