Uploaded image for project: 'PROFINET IO-Device Interface'
  1. PROFINET IO-Device Interface
  2. PSPNDIF-56

Parameter Speedup service response not handled properly

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V0.0.1.0, V1.0.0.0
    • Fix Version/s: V1.0.0.1, V1.1.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When a Parameter Speedup service response is received an invalid internal handling might result in GCI adapter lockup. The problem occurs in case of advanced startup when an ARFSUBlock is part of the Connect Request.