Set Communication Status service not working properly on netX912

    Details

    • Account:
      netX 912 (NETX912)

      Description

      For netX912 the response of Set Communication Status service is not handled. Therefore the service indication is sent only once at system startup. As a result, the communication status is not properly updated within the DPM and cifx api functions may return an unexpected result.