Details
-
Type:
Bug
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V1.7.0.0
-
Fix Version/s: V1.7.4.0, V1.8.1.0 (trunk)
-
Component/s: None
-
Labels:None
-
Account:SPC Profinet Slave V5 operational (SPCPROFINE)
Description
The section about I&M data in Protocol API Manual states that for Profile_Specific_Type the implementation will use value 5 (which is correct).
However, the manual states this is for "Generic Device", which is incorrect. According to Profinet Protocol specification value 5 stands for "Interface Module or Interface Submodule". This shall be corrected in Protocol Manual.