Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.5.2.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      OEM parameter type 23 allows configuring one additional I&M0 dataset for profile specific use. The service however uses only API and does not allow specification of Slot & Subslot the I&M data should be attached to. In addition, the document needs to be improved:

      • The definition for ParameterType 23 misses a statement that only one additional I&M0 dataset is possible. In total, the stack thus supports 2 I&M0 datasets, one for API 0 and one for an additional API.
      • The service definition shall state the usecase for this service: Application with an application profile with its own API !=0 and minimum I&M requirements to be handled by the stack. Thus only I&M0 is available for the API != 0

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: