Uploaded image for project: 'PROFINET IO-Device Interface'
  1. PROFINET IO-Device Interface
  2. PSPNDIF-227

Accept TLV based database file which does not contain ChannelInit

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.5.1.0
    • Fix Version/s: V1.5.1.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Current implementation only accepts a TLV based database if the last packet in TLV database is HIL_CHANNEL_INIT_REQ. If this requirement is not met, the database evaluation is aborted.

      With this ticket, the behavior shall be changed as follows:

      • if last packet in database is HIL_CHANNEL_INIT_REQ, simply ignore it
      • if HIL_CHANNEL_INIT_REQ is not part of database, accept the database
      • after database evaluation, if no error is found, activate the configuration parameters found in database

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: