Add new Set OEM Parametertype to enable additional DCP Reset modes

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.5.1.0
    • Fix Version/s: V1.5.1.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      A new Set OEM Parametertype shall be added. If used, it shall enable support for DCP Reset modes 1, 3, 4 and 8 in both, PNDIF component and Profinet Core. It shall not be possible to only enable a subset of the Reset modes.

      By default, if this new Set OEM ParameterType is not used, PNDIF and Profinet Core shall still only support the DCP Reset mode 2.

      This Set OEM Parametertype shall only be useable with "Busstate off". The value shall survive ChannelInit sequence.