Uploaded image for project: 'PROFINET IO-Device Interface'
  1. PROFINET IO-Device Interface
  2. PSPNDIF-186

Unexpected PNIO status code when writing I&M0/I&M5 records

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.4.1.0
    • Component/s: None
    • Labels:
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When testcases write I&M5 records to validate proper pnio status codes, a wrong status 0xdf81400. The problem is caused by the firmware which tries to parse the I&M5 block in the first place. However, I&M5 is never a writeable recor thus the content should be ignored. In a similar fashion, writes to I&M 0 are rejected with wrong error status 0xDF80B102.

       

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  AMesser Andreas Messer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: