when DDP OEM parameterization is used, all defined DDP OEM options need to be set (not only those relevant for Profinet)

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.3.1.0
    • Component/s: None
    • Labels:
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      A new generic Hilscher definition states, that the DDP OEM parameters shall only be accepted as valid if all existing parameters are set, even those not required by a specific protocol stack.

      As consequence if DDP OEM parameters are used, all parameters shall be set by application. The ulOemDataOptionFlags shall be equal to

      HIL_PRODUCT_DATA_OEM_IDENTIFICATION_FLAG_SERIALNUMBER_VALID | HIL_PRODUCT_DATA_OEM_IDENTIFICATION_FLAG_ORDERNUMBER_VALID | HIL_PRODUCT_DATA_OEM_IDENTIFICATION_FLAG_HARDWAREREVISION_VALID | HIL_PRODUCT_DATA_OEM_IDENTIFICATION_FLAG_PRODUCTIONDATA_VALID