Reject/Ignore invalid manufacturer specific diagnosis values

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.3.1.0
    • Component/s: None
    • Labels:
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Considering the allowed codings for manufacturer specific diagnosis, the specification requires that:

      • For each diagnosis source only one diagnosis entry per USI is allowed
      • the channelnumber must be "0x8000" ("Submodule")
      • direction must be "manufacturer specific"
      • accumulative must be "false"
      • severity must be "fault"

      Currently the implementation accepts invalid combinations.