Details
-
Type: Change
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: V1.3.0.0
-
Component/s: GCI Adapter, Packet Interface
-
Labels:
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
Due to new definitions for expected firmware behavior the SetOem ParameterType 17 is obsolete. The new firmware behavior defines that on "bus off" the IP stack stays configured. This is the same behavior that was previously activated by ParameterType 17. The IP address shall be configured to "0.0.0.0" Only in case a Channel Init is executed with configuration (database or packet).
When this service is received, it shall be rejected with "Invalid Parameter".
Attachments
Issue Links
- is blocked by
-
PSPNSV5-150 Change behavior of bus state changes regarding to IP stack handling
- Closed
- relates to
-
PSPNSV5-152 Upgrade Profinet Device Interface to V1.3.0.0
- Closed