Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-947

reading write-only object CombinedObjectContainer is rejected with wrong error code for interface submodules

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.17.0.3, V1.17.2.0 (trunk)
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Core V1 operational (SPCPROFINET)

      Description

      When the write-only record object CombinedObjectContainer is read from an interface submodule, the request is rejected with "access denied" (0xDE80B600). For other submodules, the request is rejected with "invalid index" (0xDE80B000).

      It is expected, that the request is always rejected with "invalid index", regardless of the type of submodule.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: