Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-872

Relax Multiple Write Length checking

    Details

    • Account:
      SPC Profinet Core V1 operational (SPCPROFINET)

      Description

      The current implementation of Multiple Write will cause an error response if the last parameter record in a multiple write request is zero padded to 32 bit alignment. 

      Our current interpretation of Profinet Specification is, that the last parameter record of a multiple write should not be followed by any padding since there is no more data in the RPC request. However as discussed internally, the record checking will be relaxed such that a trailing padding is accepted if it has correct length.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: