Details
-
Type:
Change
-
Status: Closed
-
Priority:
Minor
-
Resolution: Fixed
-
Affects Version/s: V1.16.1.0
-
Fix Version/s: V1.16.0.4, V1.16.4.0 (V1.17.0.x branch), V1.17.1.x (trunk)
-
Component/s: None
-
Labels:None
-
Account:SPC Profinet Core V1 operational (SPCPROFINET)
Description
The current implementation of Multiple Write will cause an error response if the last parameter record in a multiple write request is zero padded to 32 bit alignment.
Our current interpretation of Profinet Specification is, that the last parameter record of a multiple write should not be followed by any padding since there is no more data in the RPC request. However as discussed internally, the record checking will be relaxed such that a trailing padding is accepted if it has correct length.
Attachments
Issue Links
- blocks
-
PSPNSV4-1646 Upgrade Profinet Core to V1.16.0.5
-
- Closed
-
-
PSPNSV5-815 Upgrade Profinet Core to V1.16.0.5
-
- Closed
-
-
PSPNSV5-819 Gracefully handle trailing padding in write record request
-
- Closed
-