Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V1.15.0.0
-
Fix Version/s: V1.15.0.7, V1.15.5.0, V1.16.1.0 (trunk)
-
Component/s: Device
-
Labels:None
-
Account:SPC Profinet Core (SPCPROFINET)
Description
In the case that System Redundancy is enabled and the tag list entry element "Number of additional IO AR" is set to zero, and thus the Shared Device feature is disabled, the stack allocates the resources for two ARs, the second of which is exclusively for the SR, so either an IO-AR or a SR-AR (ARset) can be established; a mixture of the two should result in an error.
Currently, two IO-ARs may be established simultaneously.
Attachments
Issue Links
- blocks
-
PSPNSV4-1558 Upgrade Profinet Core to V1.15.5.0
- Closed
- requested by
-
PSPNSV4-1565 SystemRedundancy firmware can establish 2 non-SR IO ARs, even if taglist disables SharedDevice
- Closed
-
PSPNSV5-697 SystemRedundancy firmware can establish 2 non-SR IO ARs, even if taglist disables SharedDevice
- Closed