Singleport PNS firmware returns PDInterfaceMRPDataReal although MRP is not supported.

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.15.0.0
    • Fix Version/s: V1.15.0.5, V1.15.2.0
    • Component/s: Device
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      When reading PDRealData record, the single port firmware returns the subblock PDInterfaceMRPDataReal, although MRP is not supported.

      However, only PDRealData record (0xf841) is affected.  Reading PDInterfaceMRPDataReal (0x8052) record is rejected as expected with errorcode "Invalid Index".