Memory corruption in case of large cyclic data

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V1.6.0.0, V1.7.0.0, V1.8.0.0, V1.9.0.0, V1.10.0.0, V1.11.0.0, V1.12.0.0, V1.13.0.0, V1.14.0.0, V1.15.0.0, V1.15.1.0
    • Fix Version/s: V1.15.0.4, V1.15.2.0
    • Component/s: Common, Device
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      When the CPM is configured for C_SDU lengths of 1437 to 1440 byte, a buffer overflow occurs. As a consequence unexpected firmware behavior of any kind occurs.

      The problem affects all Profinet Device firmware and can be triggered by Profinet IO Controller with sending a Connect with an Output IOCR data length of 1437 to 1440 byte.

      The Profinet IO Controller is not affected since it uses a different data path.