Reading object CIMSNMPAdjust after a ResetFactorySettings request delivers unexpected data

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.15.0.0
    • Fix Version/s: V1.15.0.4, V1.15.2.0
    • Component/s: Device
    • Labels:
      None
    • Account:
      SPC Profinet Core V1 operational (SPCPROFINET)

      Description

      When object CIMSNMPAdjust was written by an AR and afterwards, a DCP ResetFactory (DCPOption 5, DCPSuboption 6, BlockQualifier 4 (ResetMode 2) is issued, the stack correctly disabled SNMP (which is factory default for SecurityClass 1 enabled state).

      However, if in this state object CIMSNMPAdjust is read via network, a response is sent back stating SNMP is disabled. Expected result is an empty record (as content of CIMSNMPAdjust was cleared).

       