Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-726

PTCP memory resources accessed even if PTCP is not used and thus unavailable

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.14.0.0
    • Fix Version/s: V1.14.0.12, V1.14.1.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      In case the Protocol stack is used together with a non-PTCP capable ethernet backend, PTCP is not initalized on startup. As consequence, no PTCP resource shall be accessed at runtime.

      However, access to PTCP resources is done at later point in time leading to invalid memory access and (as consequence) to a crash.