Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-695

Multicast frames may be reported twice to the 2nd chassis

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.15.0.0
    • Component/s: Device
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      When NDIS is enabled, multicast frames can be reported twice to the registered applications. In transmit mode they are reported through the 1st chassis, while in receive mode they are reported through the 2nd chassis. This results that the same frames being released twice, which in turn can cause the stack to get stuck in an infinite loop.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    RAamidi Redouane Aamidi
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: