Some of the stored plug alarms are not processed after the PrmBegin sequence

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.14.0.2, V1.14.1.0
    • Component/s: Controller
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      Not all Plug sequences which are interrupted by PrmBegin are resumed by IO-Controller stack when PrmBegin sequence is completed.

      According to Profinet specification, the IO controller shall store plug alarm temporarily until PrmBegin is finished and process it immediately afterward.

      In case of many configured IO-Devices and high network load, this currently does not occur for all stored plug Alarms.