Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-541

Disable SNMP by factory default for Security Class I

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.13.2.0
    • Component/s: None
    • Labels:
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      As of specification 2.4 MU 3, the security behavior has been changed. For Security Class I supporting devices, SNMP is off by factory default value. However, for backwards compatibility, as soon as an AR is established without writing the PDSecurityAdjust record, SNMP will be enabled for the device.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: