Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-515

Add support for Combined Object Container

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.13.1.0
    • Component/s: Controller
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      In order to support System redundancy, the IO-Controller is required to write PDEV record data using Combined Object Container Record with index 0x80B0.

      Optional for non-SR and only for PDev submodules, COC should be supported also in case of Advanced AR and ARProperties.CombinedObjectContainer is set.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  RAamidi Redouane Aamidi
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: