Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-503

On netX52 RUN state sometimes not reached by RTC3 Port statemachine

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.13.0.4, V1.13.1.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      When an AR connects with different IR Data UUID but same PTCP Subdomain UUID the RTC3 Port State Machine might be stuck in state off. The problem occurs with netX52 chipset only and is related to XIP mode.

      It is expected that in such case the state behaves as expected an switches to RUN if possible.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: