No response to release.req if WDT error is detected simultaneously

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.9.0.0, V1.10.0.0, V1.11.0.0, V1.12.0.0
    • Component/s: Device
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      When release.req is received shortly after the WDT error is detected, but the AR is not yet completely terminated, it can happen that no release.rsp is sent to the IO controller and this  may also result  that the affected AR can no longer be re-established.