Receiving an unsorted expected submodule list within connect.req leads to unexpected ModuleDiffBlock

    Details

    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      IO device may incorrectly report a ModuleDiffBlock with "no submodule" for existing submodules when an unsorted list of expected submodules by api, slot and subslot within a connect.req is detected.

      According to PROFINET specification, the Expected Submodules block need not be sorted.