Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-395

Process data handling started to early for IRT applications

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V1.2.0.0
    • Fix Version/s: V1.9.0.11, V1.10.0.4, V1.10.1.0
    • Component/s: Common
    • Labels:
      None
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      The processing of the IRT data is started before the frame reception/transmission has been fully finished. As a result the process data might be delayed by one cycle and/or the device might transmitt only each other frame. The problem depends on various conditions including:

      • computing power of the used netx chipset
      • topology of the network
      • connection history of the device
      • length of the frames

       

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: