Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-338

[System Redundancy] Reject PrmBegin request with empty SubmoduleList block

    Details

    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      Definition for PrmBegin service with empty SubmoduleList block is now clarified by PI. 

      Now according to service specification, an empty submoduleList is not allowed. The device shall reject the PrmBegin request with empty submodule list block  with error code " Invalid number of submodule (0xDD811904)".

       

      This only applies for IO AR and System Redundancy AR. 

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  RAamidi Redouane Aamidi
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: