Uploaded image for project: 'PROFINET Core'
  1. PROFINET Core
  2. PSPNCORE-335

Unexpected Acyclic service indication during other service pending

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V1.9.0.2, V1.10.0.0
    • Component/s: None
    • Labels:
    • Account:
      SPC Profinet Core (SPCPROFINET)

      Description

      Analysis of the implementation has show a major issue with internal acyclic service serialization: When an AR is aborted, the current implementation internally returns an pending acyclic service with corresponding error code. Additionally, the service is considered finished and serialization of other pending issues continues. Thus there can occur a condition, where the application has not yet confirmed an acyclic service while a new acyclic service is indicated.

       

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  AMesser Andreas Messer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: