      According to Profinet specification the field AM_DeviceIdentification shall have the following order:

      DeviceIdentification.Organization, DeviceIdentification.VendorID, DeviceIdentification.DeviceID, DeviceIdentification.DeviceSubID

      However, the PDU definition is in wrong inverse order:

      DeviceIdentification.DeviceSubID, DeviceIdentification.DeviceID, DeviceIdentification.VendorID, DeviceIdentification.Organization