Uploaded image for project: 'POWERLINK Controlled Node V3'
  1. POWERLINK Controlled Node V3
  2. PSPLSV3-26

Async MTU size cannot be changed from the bus

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.0.1.0
    • Fix Version/s: V3.2.0.0
    • Labels:
      None
    • Account:
      SPC Powerlink Slave (SPCPOWERLINKSL)

      Description

      Powerlink specification defines that the Async MTU size should be configurable from the bus. The new value for the MTU size can be set by the master on runtime. However this value is only activated when the NMT state machine goes through the state NMT_GS_RESET_CONFIGURATION again.
      A change in the TCP/IP stack is mandatory here.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    MAzarkan Maher Azarkan
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: