Uploaded image for project: 'POWERLINK Controlled Node V3'
  1. POWERLINK Controlled Node V3
  2. PSPLSV3-24

Wrong value answered to read SDO request to CumulativeCnt and ThresholdCnt of the Loss of Frames, CRC and Collision error object

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.0.1.0
    • Fix Version/s: V3.1.0.0
    • Labels:
      None
    • Account:
      SPC Powerlink Slave (SPCPOWERLINKSL)

      Description

      NMT component answers to this read requests with the values stored in the own resources. These are not used in other place in the stack. The real value is handled and stored in the DLL state machine (DrvEth Adapter).
      No more resources allocation for these parameters is needed in the NMT component. Read and Write requests will be processed using IOCTL commands.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MAzarkan Maher Azarkan
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: