      Description

      Add support of Multiplexed feature according to DS301 V1.3.0. This includes following steps:

      • DLL:
        • Adapt recognition of Loss of PReq errors to multiplexed cycles
        • Handle the Multiplexed flags in SoC, PReq and PRes frames.
      • OD:
        • Add object 0x1F9B (NMT_MultiplCycleAssign_AU8)
        • Check if object 0x1F81 (NMT_NodeAssignment_AU32) is needed
      • API:
        • Use the parameter ulFeatureFlags to activate the Multiplexed feature.
        • Check if application has permission to define the multiplexed cycle on it self. If yes, add parameter for it.
      • Test:
        • Certification Test with B&R PLC following the specifications of "POWERLINK-Certification_Test_Procedure_V1.0 Chapter 3.3.2"
        • Automatic tests with internal Low Level Test Master
      • Documentation:
        • Extend the API Manual within the new information