Uploaded image for project: 'POWERLINK Controlled Node V3'
  1. POWERLINK Controlled Node V3
  2. PSPLSV3-111

Object 0x1C14 (LossOfSoCTolerance) can not be set to its high limit 0xFFFFFFFF

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.1.0.0
    • Fix Version/s: V3.2.0.0
    • Labels:
      None
    • Account:
      SPC Powerlink Slave (SPCPOWERLINKSL)

      Description

      Since the value of LossOfSoCTolerance is stored in the DLL in 10ns base, a part of the original value is lost, when receiving an SDO wrtie request. The correct way is to store this value in the orginal form (ns based) in the DLL.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  MAzarkan Maher Azarkan
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: