Uploaded image for project: 'OpenModbus TCP V5'
  1. OpenModbus TCP V5
  2. PSOMBV5-153

Option to read out current assigned IP address.

    Details

    • Type: New Feature
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V5.1.1.0, V5.2.0.0
    • Labels:
      None
    • Account:
      SPC Open Modbus TCP (SPCOPENMODTCP)

      Description

      The host application can read the current IP address from the stack. If the stack is configured to
      retrieve the IP address via DHCP or BOOTP, the host application can read the assigned IP address.
      To read the current IP address the common socket API command
      SOCK_CMD_GETIFADDRS_REQ/CNF can be used. This command is described in the Socket API
      manual. Note: The command SOCK_CMD_GETIFADDRS_REQ/CNF must be sent to the channel 1
      „Network Service Channel“ of the dual-port memory. 

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    MKroll Mirko Kroll
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated: