Uploaded image for project: 'LWIP based TCP/IP'
  1. LWIP based TCP/IP
  2. PSLWIP-409

NetIdent protocol not responded when in different subnet

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V5.0.1.0
    • Fix Version/s: V5.1.0.2, V5.1.1.0
    • Labels:
      None
    • Account:
      SPC TCP_IP (SPCTCPIP)

      Description

      When the implementation receives a netIdent request with a master ip with different subnet than configured for the corresponding network interface, the request will not be responded. The problem occurs because the implementation does not use broadcast destination when sending the response.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: