When a switch with fragmented ethernet buffers is used, it can happen, that lwIP still uses buffers which it has released before. The problem ist caused by wrong reference counting during zero copy buffer handling.
The problem can be observed with Profinet Device firmwares for netX50/netX100/netX500 chipsets since these have a split-buffer switch.