wrong value returned for remote NameOfStation if read via SNMP and remote peer is a non-Profinet device

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V4.4.0.0
    • Fix Version/s: V4.4.0.13, V4.4.1.0
    • Component/s: LLDP Task
    • Labels:
      None
    • Account:
      SPC TCP_IP (SPCTCPIP)

      Description

      If the neighbor connected sends LLDP frames where the LLDP_ChassisID uses coding "locally assigned" (in the same way as Profinet devices do) but the neighbor is not a Profinet device, this LLDP_ChassisID is mistakenly reported as NameOfStation if the neighbor NameOfStation is read via SNMP access to LLDP Remote MIB.

      It is expected that no remote NameOfStation is reported in this case.