Uploaded image for project: 'EtherNet/IP Adapter V5'
  1. EtherNet/IP Adapter V5
  2. PSEISV5-202

SelectAcd attribute of TCP/IP object is applied without device reset (certification issue)

    Details

    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      According to the spec, the setting of the attribute value should become effective with the next device reset. With the current implementation, it becomes active already during runtime in case of a subsequent change of attribute 3 or attribute 5 of the TCP/IP object.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    MBommert Marc Bommert
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: