Use 0 as initial sequence number for IO connections and check for a sequence number gap

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.2.0.1, V3.2.1.0, V3.3.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      When targets and originators begin producing data on a transport class 0 or 1 connection, the
      initial Encapsulation Sequence Number shall be 0.
      Gap. For more information see CIP Volume 2 Edition 1.19 Chapter 3-4.1 "CIP Transport Class 0 and Class 1 Packet Ordering".