Identity object attribute 6 (Serial number) is 0 after Identity reset

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.7.0.3, V3.7.1.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC EthernetIp Slave (SPCETHERNE)

      Description

      If configuration is performed by the AP-Task, a stack memory overflow occurrs during protocol-stack configuraton.

      This overflow does not result in a malfunction or errornous state right away. There is only one known affect that after a CIP Identity reset service the serial number cannot be read from the DDP (Device Data Provider) anymore, which results in the serial number (Identity attribute 6) to be 0.